Fire-magic Diamond Single Sideburner 32794-1 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Grilles Fire-magic Diamond Single Sideburner 32794-1 Series. Fire Magic Diamond Single Sideburner 32794-1 Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
09-41
INSTALLER: Leave these instructions with consumer.
CONSUMER: Retain for future reference.
INSTALLATION AND OPERATING
INSTRUCTIONS
Important: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or the fi re department.
WARNING:
1. Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
CODE AND SUPPLY REQUIREMENTS: This appliance
must be installed in accordance with local codes and
ordinances, or, in the absence of local codes, with the
latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), or Natural Gas and Propane Storage and Handling
Installation Code (CSA-B149.1).
This appliance and its dedicated manual shutoff valve
must be disconnected from the gas-supply piping
system when testing the syst
em at pressures in
excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas-
supply piping system by closing its dedicated
manual shutoff valve during any pressure testing
of the gas-supply system at pressures up to and
including ½ psig (3.5 kPa).
All electrical outlets in the vicinity of the appliance
must be properly grounded in accordance with local
codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.1, whichever
is applicable.
Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
WARNING:
Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage. For proper installation, refer
to the installation instructions. For assistance
or additional information, consult a qualifi ed
professional installer, service agency, or the
gas supplier.
Proper operation of your appliance
requires prompt and periodic
maintenance. See the CARE &
CLEANING section for details.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
WARNINGS AND SAFETY CODES
Certifi ed to: ANSI Z21.58b-2012
CSA 1.6b-2012
REV 2 - 1502100745
L-C2-378
SINGLE SIDEBURNER
diamond series
32794-1 Series
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - SINGLE SIDEBURNER

109-41INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.INSTALLATION AND OPERATING INSTRUCTIONSImportant: READ

Page 2 - AVERTISSEMENT:

10The control panel MUST remain removable for servicing (see PARTS LIST).THIS UNIT MUST NOT BE LOCATED IN A FULLY ENCLOSED AREA OF ANY KIND.ENSURE PR

Page 3 - CONTENTS

11FOR YOUR SAFETY, you must provide the openings listed below for drainage, replacement air, and cross-ventilation of any storage area exposed to poss

Page 4 - SINGLE SIDEBURNER PARTS LIST

12CONNECT THE GAS SUPPLYFor propane cylinders:For connecting a propane unit to a portable propane tank, read the safety warnings and follow the instru

Page 5 - FRONT VIEW

13INSTALLATION (cont.)CONNECT TO A POWER SOURCECAUTION: Improperly connected wires will cause damage to the unit and may result in property damage an

Page 6 - MODEL SPECIFICATIONS (cont.)

14POWER SUPPLY (MULTIPLE ACCESSORY UNITS)The previous section covers in detail how to individually connect this accessory unit to an Echelon grill pow

Page 7

15ELECTRICAL SAFETYTo protect against electric shock, do not immerse cord or plugs (if equipped) in water or other liquid.Unplug from the outlet (if a

Page 8

16Fire Magic units are equipped with orifi ces for natural gas, unless otherwise indicated. For use with propane gas, smaller orifi ces must be installe

Page 9 - INSTALLATION REQUIREMENTS

17Air shutters are preset at the factory based on the gas the sideburner is built to burn. However, altitude or other local conditions may require air

Page 10 - L-C2-378

18ULFig. 18-1 type coupleur rapide de fi l de point culminant d’IValvede décompressionQCC Type 1 ValveAjustage de précision en laiton de fi l de point c

Page 11 - ENCLOSURE REQUIREMENTS

19ULFig. 19-1 Type I Acme thread quick couplerPressure relief valveQCC Type 1 valveBrass Acme thread fi ttingLiquid level indicator (optional)Hand nut

Page 12 - INSTALLATION

2INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRECertifi é à la norme: ANSI Z21.58b-2012 CSA 1.6b-2012DANGER:SI VOUS SENTEZ LE GAZ :1. Coupez l

Page 13 - INSTALLATION (cont.)

20ARRÊT DU UNITÉPour couper le unité, diminuez chaque bouton de commande de valve et tout en pressant tour il dans le sens des aiguilles d’une montre

Page 14

21SHUTTING OFF THE UNITTo shut off the unit, depress each valve control knob and while pressing turn it clockwise to the OFF position.Always close th

Page 15

22Fig. 22-1 - Wipe with grainPROTECTING YOUR APPLIANCE FROM THE WEATHERAn optional cover will protect your appliance when not in use. (Allow to cool b

Page 16 - CONVERTING THE GAS TYPE

23This unit comes from the factory confi gured for one type of gas, as marked on the label located behind the control panel, or on the interior of the

Page 17 - AIR SHUTTER ADJUSTMENT

24To remove the control panel:1. Turn the control knob to the OFF position and turn off the gas supply to the unit. 2. Turn off the light switch a

Page 18 - CYLINDRE ET CONDITIONS ET

25TROUBLESHOOTINGIf you have trouble with this Fire Magic® unit, please use this list to identify the problem. By trying one or more of the solutions

Page 19 - QUICK COUPLER OPERATION

26Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Quality Check Date:_________________Burner Orifi ces Nat. L.P. Leak

Page 20 - Fig. 20-2 - Éclairage manuel

3CONTENTSREV 2 - 1502100745L-C2-3781 WARNINGS AND SAFETY CODES4 SINGLE SIDEBURNER PARTS LIST5 COUNTERTOP OVERHANG5 MODEL SPECIFICATIONS6 COMBUSTIBL

Page 21 - MANUAL LIGHTING

4REV 2 - 1502100745L-C2-378Item Description Part No. Qty.1.Single sideburner cover 3279-07 12.Porcelain cast iron cooking grid 3550 1orSta

Page 22 - CARE & CLEANING

5▲ The increased dimensions for combustible enclosures allow for a required air gap along the sides and rear of the unit. See the COMBUSTIBLE ENCLOSUR

Page 23

6SUBSTRATEWhen adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:Substrate Behind Control PanelS

Page 24 - CONTROL PANEL REMOVAL

7MODEL SPECIFICATIONS (cont.)Note: In addition, a wire diagram for this unit can also be found affi xed to the inside of the control panel.REV 2 - 150

Page 25 - TROUBLESHOOTING

8ELECTRICAL CONNECTIONSA 120VAC (15 AMP minimum) Ground Fault Circuit Interrupter (GFCI) GROUNDED 3-wire receptacle (not included) is required within

Page 26 - WARRANTY

9Installation must be performed by a qualifi ed professional service technician.This unit is designed for outdoor use only. DO NOT use this unit inside

Commentaires sur ces manuels

Pas de commentaire